About
This is a customer specific MotoLogix setup with:
- Custom PLC with VARAN.
- Various customer files pre-loaded by Yaskawa.
- and more
File information
Files supplied by the customer:
| File | CRC |
|---|---|
YSFLOGIC.DAT | 0438869801 (system)3758204266 (user) |
IPNETCFG.DAT | - |
Software version
YAS5.22 (exact match).Setup steps
Install fieldbus board
Mount the option board in the robot controller.Setup MotoLogix
Activate the (paid) option function (by Yaskawa) and setup MotoLogix for the desired fieldbus and PLC architecture.endianness:littleSet parameters
Set the internal parameters required for MotoLogix usage.
The setup process requires the robot controller to be in maintenance mode
and a sufficient authorization level (management or higher).
Read more...
Activate maintenance mode:
- Power off
- Press (and hold) main menu
- Power on
- Release main menu when the beeping sound is heard (usually within a few seconds)
Change the authorization level:
- system » security » select
- select the desired level using ▼ ▲ » select
- enter the password and press enter
Additional steps
This setup requires a few additional (customer specific) steps.
The following step(s) of the setup process requires the robot controller to be
in normal mode and a sufficient authorization level (safety or higher).
Read more...
Activate normal mode:
- Power off
- Power on
Change the authorization level:
- system info » security » select
- select the desired level using ▼ ▲ » select
- enter the password and press enter
Load customer file: Safety Logic Circuit
Load the suppliedYSFLOGIC.DATinto the controller:
ex. memory » load » I/O data » YSFLOGIC.DATLoad customer file: LAN configuration
Load the suppliedIPNETCFG.DATinto the controller:
ex. memory » load » system data » IPNETCFG.DATAs this step sets the desired customer specific IP address, this step has to be done after setting up OPC-UA.Verify Safety Logic Circuit
Make sure the file was loaded properly by checking some content is available:
safety func. » safety logic circuitIn case there is no content: Reload the file.Confirm Safety Logic Circuit
Save and confirm: write » confirm
Install fieldbus board
Yaskawa robot controllers use various fieldbus solutions:
| type | description |
|---|---|
PCI | Large form factor option board |
PCIe | Compact form factor option board |
cpu board | Software option (uses the built-in LAN port) |
Mounting the CIFX board
PCIe board.
Read more...
This board can be mounted in the following installation frames (riser boards):
| type | description |
|---|---|
JANCD-ABB02-E | 2xPCIe |
JANCD-ABB04-E | 1xPCI, 1xPCIe |
Loosen the screws and remove the installation frame from the CPU rack:

Installation frame Insert the PCIe card into the corresponding slot (1 or 2) and tighten the screw:

Insert PCIe card into the slot Install the installation frame into the CPU rack and fasten it again with the screws:

Installed installation frame
Setup MotoLogix
Open the MotoLogix option function settings: system » setup » option function » motologix

MotoLogix option function Customers: Please contact Yaskawa if the MotoLogix option function is not available in the list.Activate the MotoLogix option function:
This requiresYaskawaauthorization level and cannot be changed by the customer.
MotoLogix settings Enter the settings:
item value FUNCTION ENABLEDCONNECTION TYPE VARANENDIANNESS LITTLECustomers can disable MotoLogix afterwards by settingFUNCTIONtoDISABLED.TheENDIANNESS(byte order) depends on the PLC cpu architecture.Disable the SRCI option function (if applicable):
item value SRCI OPTION NOT USEDSRCI FUNCTION DISABLEUse enter to confirm and leave the settings screen.
Setup fieldbus
CIFX board settings
Read more...
Open the board settings: system » setup » option board » CIFX 50E-RE

Option boards Enter the settings:

VARAN settings item value CIFX 50E-RE USED (MotoLogix)IO SIZE + MotoLogix 0 byte + 436 byteFIELDBUS VARANCustomers can adjust these default settings to their needs.
Example: To add an optional non-MotoLogix data packet of e.g.
32 byteset the value to32 byte + 436 byte.The size of theMotoLogixdata packet is fixed and shall not be changed.Adding a non-MotoLogix data packet might require to change/shift the address mapping of the MotoLogix data packet in the PLC.Use enter (multiple times) to confirm this- and the following screens. Make sure the IO allocation is set to
AUTOand check if the IO entries match below screenshots.
Allocation mode AUTO 
Input allocation 
Output allocation